    Manufacturer: Memmert GmbH + Co. KG

    Environmental labs

    Memmert climate technology for accredited environmental labs.

    For environmental laboratories with high sample throughput, we specify Memmert equipment for stability testing, controlled sample storage, and thermal pre-treatment. We select the oven, chamber size, and temperature and humidity profiles based on your methods, commission on-site, and document the calibration to align with your accreditation programme.

    See the applications
    Operator controlling a Memmert climate chamber via the AtmoCONTROL app on a mobile phone

    Climate equipment for accredited environmental labs.

    For Swedish environmental laboratories, we configure Memmert climate technology in three application classes. Configuration is based on the laboratory's accredited scope, daily volume, and temperature and humidity requirements per method.

    Memmert climate technology for accredited environmental labs

    German manufacturer with extensive experience in temperature and climate-controlled equipment for analytical laboratories. The Labsense portfolio includes climate chambers for stability testing and controlled sample storage, cooled incubators and incubators for temperature-dependent analyses, as well as drying ovens and vacuum drying ovens for thermal pre-treatment and dry matter determination. The equipment is configured with temperature and humidity profile, chamber size, and controller specification to meet the lab's methodology requirements. Options for data logging and calibration protocol export in formats compatible with your accreditation dossier are available.

    Full product range

    Overview of instruments, consumables, and spare parts we supply from Memmert. Click on a product to learn more and request a quote, or send a general inquiry via the contact page.

    Read more about Climate chambers HPP/ICH
    Climate chambers HPP/ICH, Memmert

    Climate & incubation

    Climate chambers HPP/ICH

    Constant temperature and humidity regulation for stability testing, ICH-compliant protocols, and controlled sample storage.

    • ±0.1 °C accuracy
    • USB logging
    • Accreditation protocols
    Read more about Incubators IN/IF
    Incubators IN/IF, Memmert

    Climate & incubation

    Incubators IN/IF

    Cooled and heating incubators for temperature-dependent analyses, microbiology, and sample storage in environmental labs.

    • 0–80 °C
    • Forced ventilation optional
    • Calibration protocol export
    Read more about Drying & vacuum ovens
    Drying & vacuum ovens, Memmert

    Climate & incubation

    Drying & vacuum ovens

    Furnaces for thermal pre-treatment, dry matter determination and vacuum drying of sensitive materials.

    • Up to 300 °C
    • Vacuum 10–1000 mbar
    • Accreditation logs
    Read more about CO2 incubator ICO
    CO2 incubator ICO, Memmert

    Climate & incubation · New platform

    CO2 incubator ICO

    Memmert's new cell culture platform, safe CO₂ incubation with precise humidity control, 180 °C sterilisation and advanced connectivity.

    • 0–20 % CO₂
    • 180 °C sterilisation
    • Ethernet/WiFi
    Read more about VO vacuum oven
    Vacuum Oven VO, Memmert

    Climate & incubation · Vacuum

    Vacuum oven VO

    Digital pressure regulation and heated shelves for rapid, gentle vacuum drying of temperature-sensitive materials, ~70 % energy saving.

    • +5–200 °C
    • 10–1100 mbar
    • VO29/49/101
    Spare shelves & calibration, Memmert

    Climate & incubation

    Spare shelves & calibration

    Spare shelves, door gaskets, water filters, USB loggers, and replacement temperature/humidity sensors for on-site calibration.

    • Original spare parts
    • On-site calibration
    • Log data export

    Applications in Nordic environmental labs.

    An accredited environmental lab works to customer delivery deadlines and accreditation traceability per method. When a climate chamber operates outside specification or an incubator loses temperature over the weekend, it becomes an accreditation risk, not just a process disruption. Configuration is based on three application clusters in the Nordic environmental lab business.

    Stability testing and controlled sample storage

    • Climate chambers for stability testing of samples and reference materials under defined temperature and humidity profiles
    • Accredited temperature-controlled storage of environmental samples prior to analysis
    • Long-term storage of reference materials and calibration standards under controlled conditions

    Incubation and temperature-dependent analyses

    • Cooled incubators for temperature-sensitive biological and chemical analyses
    • Incubators for temperature-dependent methods according to established standard protocols
    • Configuration according to your lab's scope of accreditation and method documentation

    Drying and thermal pretreatment

    • Drying ovens for dry matter determination in sludge, sediment and solid samples
    • Vacuum drying ovens for temperature-sensitive samples where open drying would alter the matrix
    • Thermal pre-treatment according to the method where the preparation step is specified in the accreditation files

    Service and support from our own engineers.

    We offer service contracts with annual planned service by our own engineers, for improved operational reliability and stable measurement quality over time. Commissioning, calibration, troubleshooting, and original spare parts are included as per agreement.

    Om vår service

    Standards, reference methods, and accreditation traceability.

    The temperature and humidity maintained by the climate chamber must be traceable to a known reference and documentable in the accreditation binder. Initial calibration is built against certified temperature and humidity sensors in the zones required by your method. Recalibration is scheduled according to an agreed service plan and documented in accordance with your quality systems.

    • ISO 17025 for traceability in calibration, documentation and reporting.
    • Temperature and humidity calibration against certified sensors in method-specific chamber zones.
    • Verification through mapping across the entire chamber volume where the method requires homogeneous climate control.
    • Documented calibration protocols that are directly usable in your accreditation or audit folders.

    Do you want to discuss climate configuration for your accredited lab?

    Describe the application, daily volume, and temperature and humidity requirements according to your method. We will provide a configuration proposal within one working day.

    Request a quote for Memmert